Project Description

New 1500 BBL Internally Coated Storage tank

New 1500 BBL Internally Coated Storage tank Stock unit

DESCRIPTION

Equipment Description & Attachments:

  • 1500BBL
  • Tank to be fabricated and tested as per API 12F specification [Modified/Non-labeled]
  • Shell, floor and roof material thickness as per API 650 calculations
  • Anchors have not been provided for wind loading
  • Emergency venting in accordance with API 2000 specification has not been provided
  • Client is responsible for ensuring equipment meets any and all regulatory requirements for site where it is to be installed.
  • Design pressure 4 oz / Design Vacuum 0.4 oz
  • Diameter: 21’ – 6”
  • Height: 24’ – 0”
  • Bottom: 1/4” thick
  • Bottom Shell: 1/4” thick
  • Remaining Shell: 3/16” thick
  • Roof: 1/4” thick (2:12 slope min) – Not back welded
  • Nameplate & bracket
  • MW – 24” x 36” API 12F type rectangular man way w/ full cover
  • 4 – Lifting lugs
  • 1 – Tailing lug
  • 1 – Lanyard tie off lug located on roof
  • 1 – Caged ladder
  • 8” round thief hatch extension (API bolt hole layout)
  • Hawkeye Model 300 sour service thief hatch (4 oz pressure / 0.4 oz vacuum)
  • Sour service gauge system c/w gauge board, indicator and PVC float.
  • 2” Skimmer line support as per client sketch
  • N1 internal piping support (6”) welded to tank floor

Connections (All connections shipped with PVC plugs or flange protectors unless noted otherwise):

  • N1 – 6” 150# RFWN double flg Outlet
  • N2 – 4” 150# RFWN double flg Skim line
  • N3 – 10” 150# RFWN double flg TBD
  • N4 – 4” 150# RFWN double flg TBD
  • N5 – 2” 150# RFWN single flg Steam connection
  • N6 – 4” 150# RFWN single flg TBD
  • N7 – 6” 150# RFWN single flg TBD
  • N8 – 6” 150# RFWN single flg TBD w/ blind
  • N9 – 2” 150# RFWN double flg Circ out
  • N10 – 3” 150# RFWN single flg Roof connection w/ blind
  • N11 A-D – 4” 150# RFWN single flg Anode connection c/w blind flange, flange insulation kit, 3” x 22# aluminum anode & pig tail wire
  • N12 – 2” 150# RFWN double flg TBD
  • N13 – 4” 150# RFWN single flg VRU
  • N14 – 2” 150# RFWN single flg TI connection – indicator and thermo ell by others
  • N15 – 4” 150# RFWN single flg TBD
  • C1-C8 – 3/4” 150# RFWN single flg Sample line connections c/w internal risers and supports
  • C9 – 2” 150# RFWN single flg Level gauge connection w/ blind tapped 1” NPT
  • C10A-B – 2” 150# RFWN single flg Float guide cable connection w/ blind tapped 1.25” NPT

Materials:

  •  Shell, floor and roof A36/44W
  •  Remaining structural A36/44W
  •  ANSI Flanges A350LF2
  •  Nozzle Pipe A333 Gr 6 Smls – STD wall
  •  Skimmer pipe support bracket A106B Smls – STD Wall
  •  Man way gaskets/fasteners Viton/Grade 5
  •  ANSI Studs/Nuts/Gaskets B7M / 2HM / 316SS flex
  •  HPW2018-Inclusive-1500 bbl Stock Page 3 of 3
  • Internal Finish:

 Blast: SSPC-SP5 White Metal Blast

 Coat: 10.0-14.0 mils DFT Devoe Devchem 253

External finish (2’ up tank shell):

  • Blast: SSPC-SP6 Brush Blast
  • Coating: 16.0 – 18.0 mils DFT Cloverdale ClovaTar22 coal

External finish (Remaining tank):

  •  Blast: SSPC-SP7 Brush Blast
  •  Prime: 1.5-2.0 mils DFT Cloverdale T101 grey primer
  •  Paint: 1.5-2.0 mils DFT Cloverdale marine enamel to match warm grey.
  •  Paint: Caged Ladder – 1.5-2.0 mils DFT Cloverdale marine enamel to match Safety Yellow

External Bottom Finish:

See options

Testing:

  •  Tank to be air/soap leak tested to 6 oz.
  •  Floor seams to be tested using vacuum box.

Additional testing requested by customer will be at extra cost.

CONTACT

Need more information? Ready to place an order?

Equipment Sales & Rental

info@inclusivenergy.com
sales@inclusivenergy.com

Phone: +1 403.444.6897
Central Alberta: +1 780.712.8881

Inclusive Energy 2000 BBL